Skip to content

More Comfort & More Confidence since 2014

Does this sound like you?

Does intimacy hurt, even when you want to be close to your partner?

Have you started avoiding intimacy because you're afraid it's going to hurt again?

Does it feel like your body is saying NO, even when your mind is saying YES?

Do tampons or pelvic exams hurt so much that you dread them?

Have you been told to "just relax," but nothing seems to make the discomfort go away?

Are you tired of wondering what's wrong and just want to feel comfortable in your own body again?

You don't have to figure this out alone.

Many women don't realize there are gentle, at-home tools designed to help them gradually become more comfortable with insertion.

They're called vaginal dilators, and they can be a helpful part of managing certain causes of painful intimacy, tightness, and insertion discomfort.

At VuVaTech, we've helped over 300,000 people explore options for greater comfort since 2014.

Not sure where to start? We make it simple.

How to Read a P2 UDS Timer: A Beginner's Guide

How to Read a P2 UDS Timer: A Beginner's Guide

Last Updated: November 14, 2026

Quick Summary

A P2 UDS timer is the maximum time a diagnostic server has to answer a request from a client in Unified Diagnostic Services. If no response arrives before the P2 window closes, the client treats the request as timed out. When a server needs more time, it sends response-pending messages, which switch the client to the longer P2 window.

  • P2 governs the first response, and P2 governs responses after a response-pending message.
  • A negative response with NRC 0x78 tells the client to keep waiting, and it is not a failure.
  • Exact timer values come from the OEM and the applicable standard, so check the ECU documentation.
  • Log request and response timestamps to tell a slow server from an impatient client.
  • Keep tester-present messages flowing so the S3 session timer does not drop the session.
We made healing easy for you.This is the first step to being comfortable again.
Shop by Symptom

Table of Contents

What the P2 Timer Means in UDS

A P2 timer is the maximum time a diagnostic server has to respond to a diagnostic request from a client in Unified Diagnostic Services (UDS).

Unified Diagnostic Services is the diagnostic protocol used by many electronic control units (ECUs) in vehicles.

In practice, the P2 value tells you how long a tester should wait before deciding a response is missing.

P2 Versus P2*: How the Two Timers Differ

The P2 and P2* timers cover the same conversation but apply in different situations.

The distinction matters because a server sometimes cannot finish a job within the normal window, such as when it is writing flash memory.

  • P2 server: the time allowed for an initial response.
  • P2 server:* the extended time allowed after a response-pending message.
  • P2 client: the time the client waits before treating a reply as missing.

Read the two timers as a pair: P2 governs the first answer, and P2* governs the answer after the server has asked for patience.

A Worked Example With Illustrative Values

Exact timer values come from the OEM and the applicable standard, so treat the numbers below as illustrative only, they are chosen to make the mechanism visible, not to describe any specific vehicle.

Suppose the client is configured with a P2 client value of 50 ms and a P2* client value of 5000 ms, and the server is configured with a P2 server value of 50 ms and a P2* server value of 5000 ms.

  1. t = 0 ms. The client transmits the request and starts its P2 client timer.
  2. t = 45 ms. The server has not finished, but it is still inside its own P2 server window, so it sends a negative response with NRC 0x78 (response pending) before the client's 50 ms expires.
  3. t = 45 ms (on receipt). The client stops its P2 client timer, restarts a P2* client timer of 5000 ms, and keeps waiting. The server likewise restarts its P2* server timer.
  4. t = 1000 ms. The erase is still running. The server sends another NRC 0x78 before its P2* server window closes, and the client resets its P2* client timer again.
  5. t = 2000 ms. The erase finishes. The server sends the final positive response, the client stops its P2* timer, and the exchange ends normally.

Notice what the timers actually measure. P2 is not a stopwatch on the whole job; it is a stopwatch on the gap between messages.

When Each Timer Starts, Stops, and Resets

  • P2 client starts when the request is transmitted and stops when any response, positive, negative, or NRC 0x78, is received.
  • P2 client starts* when an NRC 0x78 is received and resets on every subsequent NRC 0x78. It stops on the final response.
  • P2 server is the budget the server has to produce its first response after receiving a request.
  • P2 server* is the budget between consecutive NRC 0x78 messages once pending mode has begun.

Watch out: if the server sends its first NRC 0x78 at 60 ms against a 50 ms P2 client value, the client has already declared a timeout and will typically discard the late pending message, the trace then looks like a missing response even though the ECU answered.

Why the Pair Matters More Than Either Value Alone

A single mismatched value produces a confusing failure. If the client's P2* is shorter than the server's P2*, say the client waits 2000 ms while the server plans to send pending messages every 4000 ms, the client will time out between pending messages on a job that is actually progressing normally.

A useful habit when reading a trace is to measure the gap between consecutive NRC 0x78 frames and compare it with the configured P2* on both sides. If the observed gap is close to either configured value, you have found your mismatch.

Step by Step: One UDS Request and Response

Walking through one exchange makes the timer concrete. The sequence below describes a typical read request, with the timing behaviour called out at each step. The frame details are illustrative; the service identifiers and NRC values are the standard ones defined by UDS.

Automotive technician connecting a diagnostic tool to a vehicle OBD port while monitoring a laptop screen
Automotive technician connecting a diagnostic tool to a vehicle OBD port while monitoring a laptop screen
  1. The client sends a request. A scan tool transmits a service request, for example service identifier 0x22 (Read Data By Identifier), to the ECU's diagnostic address. On CAN, this travels as a single diagnostic frame inside the transport protocol; on CAN FD or DoIP the framing differs but the UDS layer above it behaves the same way.
  2. The client starts its P2 timer. The moment the request leaves the tool, the client begins counting toward its P2 client value while it waits for any response frame.
  3. The server processes the request. The ECU receives the request, validates the service identifier and the data identifier, and begins to read the requested value from memory.
  4. The server sends a positive response. If the job finishes inside the P2 server window, the server replies with a positive response, for 0x22, a frame beginning with 0x62 followed by the identifier and its current value.
  5. The client accepts the reply. The client checks that the response service identifier matches the request (0x62 answers 0x22), confirms the data identifier, stops its P2 timer, and moves on.

If step 4 does not happen before the P2 window closes, the client records a timeout. That single event is often the first clue when troubleshooting a timing fault.

Reading the Same Exchange in a Trace

A trace turns those five steps into timestamps you can measure. A healthy short exchange looks like this:

  • 0.000 s, request frame, service 0x22, data identifier 0xF190.
  • 0.018 s, positive response frame, service 0x62, data identifier 0xF190, value returned.
  • Elapsed: 18 ms. Well inside a typical P2 window, so no pending message is needed.

A long-running exchange looks different:

  • 0.000 s, request frame, service 0x31 (Routine Control), start routine.
  • 0.040 s, negative response, 0x7F 0x31 0x78 (NRC 0x78, response pending).
  • 1.020 s, negative response, 0x7F 0x31 0x78 again.
  • 2.010 s, positive response, 0x71, routine result.

Watch out: a trace that shows a request with no response at all, followed by the client immediately re-sending the same request, usually means the client's P2 expired before the first response arrived, not that the ECU ignored the request. Look for a late response frame a few milliseconds after the retry.

What Changes Across Transports

P2 and P2* are UDS application-layer concepts, so they apply identically whether the request travels over classical CAN, CAN FD, or Diagnostics over IP. What changes is the observed timing. On a busy CAN bus, arbitration delays and transport-protocol segmentation can add milliseconds between the moment the client transmits and the moment the server receives, and again on the way back.

The table below lists the key timer and response facts from the exchange walkthrough, so you can scan them quickly.

Step What happens Timing note
1. Client sends request Scan tool transmits a service request, e.g. 0x22 Starts the P2 timer immediately
2. Client waits Listens for any response frame Bounded by the P2 client value
3. Server processes Validates the request and reads the value Must finish within the P2 server window
4. Server replies Positive response, e.g. 0x62 for 0x22 Stops the client's P2 timer
5. Client accepts Checks the response service ID and data ID Exchange ends normally
If no reply in time Client records a timeout Often the first clue in troubleshooting

When a Server Needs More Time: Response Pending (NRC 0x78)

Some diagnostic jobs take longer than the normal P2 window allows. For these, the server sends a negative response with Negative Response Code (NRC) 0x78, which means "response pending." It is not a failure.

When the client receives NRC 0x78, it switches from the P2 window to the P2* window. The server can repeat this message as needed until it has a final answer.

Watch for repeated NRC 0x78 messages in a trace. They show the server is busy, not stuck.

How the S3 Server Timer Keeps Sessions Alive

The S3 server timer controls how long a non-default diagnostic session stays open without activity. If the client stops sending messages, the server eventually returns to the default session.

To keep a session alive, the client sends a tester-present message before the S3 timer expires.

Session timeouts are a common source of confusion. A test that works for a few seconds and then fails with an unexpected reset often points to S3 rather than P2.

Troubleshooting Timeouts and Timing Mismatches

Most timeout problems fall into a few patterns. Start by identifying which timer expired and in which direction.

  • Client gives up too early. The client's configured P2 or P2* value is shorter than the server actually needs. Compare the configured values with the ECU's documentation.
  • Server never sends response pending. A long job runs without NRC 0x78 messages, so the client times out. Confirm the ECU supports response pending for that service.
  • Session drops unexpectedly. The S3 timer expired because no tester-present messages were sent.
  • Mismatched values between tools. Different tools may use different timer settings. Use the same configuration when comparing results.

A good practice is to capture a trace and read the timestamps. The gap between request and response tells you whether the problem is the server being slow or the client being impatient.

Applying P2 Timing in Your Own Diagnostic Work

Start with the ECU's documentation for its P2 and P2* values, then set your tool to match.

When you build or review a test, log the timestamps of every request and response.

Keep a short checklist for each new ECU: confirm the timer values, confirm response-pending support, and confirm the tester-present interval.

For a broader foundation, review the UDS standard and your OEM's diagnostic specification.

Frequently Asked Questions

What is the P2 timer in UDS?

The P2 timer is the time a diagnostic server has to send its first response to a request from a diagnostic client. In UDS (ISO 14229), the client sends a request and waits; if the server does not answer within the P2 window, the client treats the request as timed out. The exact value is set by the vehicle manufacturer and the communication stack, and it is defined in the relevant standard and the ECU's diagnostic specification. Because the value is product-specific, check the ECU documentation or the OEM diagnostic specification for the numbers that apply to your project.

What is the difference between P2 and P2* in UDS?

P2 is the window for the initial response. P2* applies after the server has sent a Negative Response with NRC 0x78 (Response Pending), telling the client that the request is being processed and more time is needed. The extended window P2* gives the server time to finish the job and then send the full response. Both timers are defined in ISO 14229 and their values come from the ECU's specification rather than from a fixed number, so confirm them for your device.

What happens when a UDS server needs more time to respond?

The server sends a Negative Response with NRC 0x78, which means Response Pending. This tells the client to keep waiting and resets the timing so the client knows the server is still working. The server can repeat this message while it processes the request. Once the processing finishes, it sends the actual positive or negative response. If Response Pending never arrives and no answer comes within P2, the client should record a timeout and retry or report the fault.

How does the S3 server timer relate to P2 timing?

P2 and P2* control how quickly a server answers a single request. The S3 server timer is different: it controls how long a non-default diagnostic session stays active when no tester-present messages arrive. If the S3 timer expires, the server falls back to the default session. Both matter during diagnostics, but they do different jobs, and their values are set in the ECU's diagnostic specification.

Previous Post Next Post
VuVa Pelvic Support Sets

Made in the USA

We create safe, effective products that truly work — designed to help you relax, restore balance, and feel good in your body again. Our VuVa® Pelvic Floor Support Sets gently calm nerves, ease tension, and support natural pelvic healing from the inside out.